GE AF-650 GP Programming Manual page 190

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Troubleshooting
Num
Description
ber
58
Auto Tune internal fault
59
Current limit
61
Feedback Error
62
Output Frequency at Maximum Limit
64
Voltage Limit
65
Control board overtemperature
66
Heat sink temperature low
67
Option Module Configuration has Changed
69
Pwr. Card Temp
70
Illegal Drive configuration
75
Illegal Profile Sel.
76
Power Unit Setup
77
Reduced power mode
78
Tracking Error
79
Illegal PS config
80
Frequency converter Restored to Factory Settings
81
CSIV corrupt
82
CSIV parameter error
83
Illegal Option Combination
88
Option Detection
91
Analog input 54 wrong settings
246
Pwr.card supply
250
New spare parts
251
New Type Code
Table 5.1 Alarm/Warning Code List
(X) Dependent on parameter
1) Cannot be auto reset via parameter H-04 Auto-Reset (Times)
A trip is the action following an alarm. The trip coasts the motor and is reset by pressing [Reset] or by a digital input
(parameter group E-1#). The original event that caused an alarm cannot damage the frequency converter or cause
dangerous conditions. A trip lock is an action when an alarm occurs, which could damage the frequency converter or
connected parts. A trip lock situation can only be reset by a power cycling.
Warning
Alarm
Trip locked
Table 5.2 Indicator Light
DET-618D
AF-650 GP™ Programming Guide
Warning
X
X
(X)
X
X
X
X
X
X
(X)
Yellow
Flashing red
Yellow and red
02/2016 All rights reserved.
Alarm/Trip
Alarm/Trip Lock
X
(X)
X
X
X
X
X
X
X
(X)
X
X
X
X
X
X
X
X
X
X
X
Parameter
Reference
Parameter H-20 Motor
Feedback Loss Function
5
Parameter SP-59 Actual
Number of Inverter
Units
Parameter H-24 Trackin
g Error Function
S202