Parameter Lists

4.1.17 DR-## Data Readouts

Par. No. # Parameter description
DR-0#
DR-00
Control Word
DR-01
Reference [Unit]
4
4
DR-02
Reference %
DR-03
Status Word
DR-05
Main Actual Value [%]
DR-09
Custom Readout
DR-1#
DR-10
Power [kW]
DR-11
Power [hp]
DR-12
Motor Voltage
DR-13
Frequency
DR-14
Motor current
DR-15
Frequency [%]
DR-16
Torque [Nm]
DR-17
Speed [RPM]
DR-18
Motor Thermal
DR-19
KTY sensor temperature
DR-2#
DR-20
Motor Angle
DR-21
Torque [%] High Res.
DR-22
Torque [%]
DR-23
Motor Shaft Power [kW]
DR-24
Calibrated Stator Resistance
DR-25
Torque [Nm] High
DR-3#
DR-30
DC Link Voltage
DR-32
Brake Energy /s
DR-33
Brake Energy Average
DR-34
Heatsink Temp.
DR-35
Drive Thermal
DR-36
Drive Nominal Current
DR-37
Drive Max. Current
DR-38
Logic Controller State
DR-39
Control Card Temp.
DR-4#
DR-40
Trending Buffer Full
DR-45
Motor Phase U Current
DR-46
Motor Phase V Current
DR-47
Motor Phase W Current
DR-48
Speed Ref. After Ramp [RPM]
DR-49
Current Fault Source
DR-5#
DR-50
External Reference
DR-51
Pulse Reference
DR-52
Feedback[Unit]
DR-53
Digi Pot Reference
DR-57
Feedback [RPM]
DR-6#
180
Default value
4-set-up
0 N/A
All set-ups
0 ReferenceFeedbackUnit
All set-ups
0 %
All set-ups
0 N/A
All set-ups
0 %
All set-ups
0 CustomReadoutUnit
All set-ups
0 kW
All set-ups
0 hp
All set-ups
0 V
All set-ups
0 Hz
All set-ups
0 A
All set-ups
0 %
All set-ups
0 Nm
All set-ups
0 RPM
All set-ups
0 %
All set-ups
0 °C
All set-ups
0 N/A
All set-ups
0 %
All set-ups
0 %
All set-ups
0 kW
All set-ups
0.0000 Ohm
All set-ups
0 Nm
All set-ups
0 V
All set-ups
0 kW
All set-ups
0 kW
All set-ups
0 °C
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
0 °C
All set-ups
[0] No
All set-ups
0 A
All set-ups
0 A
All set-ups
0 A
All set-ups
0 RPM
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 ReferenceFeedbackUnit
All set-ups
0 N/A
All set-ups
0 RPM
All set-ups
02/2016 All rights reserved.
Change
Conver-
Type
during
sion index
operation
FALSE
0
V2
FALSE
-3
Int32
FALSE
-1
Int16
FALSE
0
V2
FALSE
-2
N2
FALSE
-2
Int32
FALSE
1
Int32
FALSE
-2
Int32
FALSE
-1
Uint16
FALSE
-1
Uint16
FALSE
-2
Int32
FALSE
-2
N2
FALSE
-1
Int16
FALSE
67
Int32
FALSE
0
Uint8
FALSE
100
Int16
TRUE
0
Uint16
FALSE
-1
Int16
FALSE
0
Int16
TRUE
1
Int32
TRUE
-4
Uint32
FALSE
-1
Int32
FALSE
0
Uint16
FALSE
0
Uint32
FALSE
0
Uint32
FALSE
100
Uint8
FALSE
0
Uint8
FALSE
-2
Uint32
FALSE
-2
Uint32
FALSE
0
Uint8
FALSE
100
Uint8
TRUE
-
Uint8
TRUE
-2
Int32
TRUE
-2
Int32
TRUE
-2
Int32
FALSE
67
Int32
TRUE
0
Uint8
FALSE
-1
Int16
FALSE
-1
Int16
FALSE
-3
Int32
FALSE
-2
Int16
FALSE
67
Int32
DET-618D