How to Program
Operating variable
Parameter DR-13 Frequency
Parameter DR-14 Motor current
2
2
Parameter DR-16 Torque [Nm]
Parameter DR-17 Speed [RPM]
Parameter DR-18 Motor Thermal
Parameter DR-20 Motor Angle
Parameter DR-30 DC Link Voltage
Parameter DR-32 Brake Energy /s
Parameter DR-33 Brake Energy Average
Parameter DR-34 Heatsink Temp.
Parameter DR-35 Drive Thermal
Parameter DR-36 Drive Nominal Current
Parameter DR-37 Drive Max. Current
Parameter DR-38 Logic Controller State
Parameter DR-39 Control Card Temp.
Parameter DR-40 Trending Buffer Full
Parameter DR-50 External Reference
Parameter DR-51 Pulse Reference
Parameter DR-52 Feedback[Unit]
Parameter DR-53 Digi Pot Reference
Parameter DR-60 Digital Input
Parameter DR-61 Terminal 53 Switch Setting
Parameter DR-62 Analog Input 53
Parameter DR-63 Terminal 54 Switch Setting
Parameter DR-64 Analog Input 54
Parameter DR-65 Analog Output 42 [mA]
Parameter DR-66 Digital Output [bin]
Parameter DR-67 Freq. Input #29 [Hz]
Parameter DR-68 Freq. Input #33 [Hz]
Parameter DR-69 Pulse Output #27 [Hz]
Parameter DR-70 Pulse Output #29 [Hz]
Parameter DR-71 Relay Output [bin]
Parameter DR-72 Counter A
Parameter DR-73 Counter B
Parameter DR-80 Fieldbus CTW 1
Parameter DR-82 Fieldbus REF 1
Parameter DR-84 Comm. Option STW
Parameter DR-85 Drive Port CTW 1
Parameter DR-86 Drive Port REF 1
Parameter DR-90 Alarm Word
Parameter DR-92 Warning Word
Parameter DR-94 Ext. Status Word
Table 2.1 Units
Status view I
This readout state is standard after start-up or initialization.
Press [Info] to obtain information about the units linked to
the shown operating variables (1.1, 1.2, 1.3, 2 and 3).
See the operating variables shown in Illustration 2.10.
16
Unit
[Hz]
[A]
Nm
[RPM]
%
V
kW
kW
Illustration 2.10 Status View I
ºC
%
A
Status view II
A
See the operating variables (1.1, 1.2, 1.3, and 2) shown in
Illustration 2.11.
°C
In the example, speed, motor current, motor power, and
frequency are selected as variables in the first and second
lines.
[Unit]
bin
V
V
[mA]
[bin]
[Hz]
[Hz]
Illustration 2.11 Status View II
[Hz]
[Hz]
Status view III
This state shows the event and action of the Logic
Controller. For further information, see chapter 3.20 LC-##
hex
Logic Controller.
hex
hex
hex
hex
Illustration 2.12 Status View III