Parameter Lists

4.1.6 P-## Motor Data

Par. No. # Parameter description
P-0#
P-01
Motor Poles
P-02
Motor Power [HP]
P-03
Motor Current
P-04
Auto Tune
P-05
Motor Cont. Rated Torque
P-06
Base Speed
P-07
Motor Power [kW]
P-09
Slip Compensation
P-1#
P-10
Slip Compensation Time Constant
P-2#
P-20
Motor Construction
P-24
Damping Gain
P-25
Low Speed Filter Time Const.
P-26
High Speed Filter Time Const.
P-27
Voltage filter time const.
P-28
Min. Current at No Load
P-3#
P-30
Stator Resistance (Rs)
P-31
Rotor Resistance (Rr)
P-33
Stator Leakage Reactance (X1)
P-34
Rotor Leakage Reactance (X2)
P-35
Main Reactance (Xh)
P-36
Iron Loss Resistance (Rfe)
P-37
d-axis Inductance (Ld)
P-38
q-axis Inductance (Lq)
P-4#
P-44
d-axis Inductance Sat. (LdSat)
P-45
q-axis Inductance Sat. (LqSat)
P-46
Position Detection Gain
P-47
Torque Calibration
P-48
Inductance Sat. Point

4.1.7 H-## High Perf Parameters

Par. No. # Parameter description
H-0#
H-01
Option Detection
H-03
Restore Factory Settings
H-04
Auto-Reset (Times)
H-05
Auto-Reset (Reset Interval)
H-07
Accel/Decel Time 1 Type
H-08
Reverse Lock
H-09
Start Mode
H-2#
H-20
Motor Feedback Loss Function
DET-618D
AF-650 GP™ Programming Guide
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
ExpressionLimit
[0] Asynchron
140 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
ExpressionLimit
ExpressionLimit
Default value
[0] Protect Option Config.
[0] Normal operation
[0] Manual reset
ExpressionLimit
[0] Linear
[0] Clockwise
ExpressionLimit
ExpressionLimit
02/2016 All rights reserved.
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
Type
0
Uint8
-2
Uint32
4
-2
Uint32
-
Uint8
-1
Uint32
67
Uint16
1
Uint32
0
Int16
-2
Uint16
-
Uint8
0
Int16
-2
Uint16
-2
Uint16
-3
Uint16
0
Uint16
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
-6
Int32
-6
Int32
-6
Int32
-6
Int32
0
Uint16
-
Uint8
0
Int16
Type
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
169
4