Parameter Descriptions
LC-01 Start Event
Select the boolean (true or false) input to activate Logic
Controller.
Option:
[40]
Drive stopped
3
3
[41]
Reset Trip
[42]
Auto-reset Trip
[43]
Ok key
[44]
Reset key
[45]
Left key
[46]
Right key
[47]
Up key
[48]
Down key
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[76]
Digital input
x30 2
[77]
Digital input
x30 3
[78]
Digital input
x30 4
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100] RS Flipflop 6
[101] RS Flipflop 7
136
Function:
A stop command (jog, stop, quick stop,
coast) is issued – and not from the Logic
Controller itself.
A reset is issued.
An auto reset is performed.
[OK] is pressed. Only available on the
graphical LCP.
[Reset] is pressed. Only available on the
graphical LCP.
[◄] is pressed. Only available on the
graphical LCP.
[►] is pressed. Only available on the
graphical LCP.
[
] is pressed. Only available on the
graphical LCP.
[
] is pressed. Only available on the
graphical LCP.
Use the result of comparator 4.
Use the result of comparator 5.
Use the result of logic rule 4.
Use the result of logic rule 5.
Use the value of x30/2 (General Purpose
I/O OPCGPIO).
Use the value of x30/3 (General Purpose
I/O OPCGPIO).
Use the value of x30/4 (General Purpose
I/O OPCGPIO).
See chapter 3.20.2 LC-1# Comparators.
See chapter 3.20.2 LC-1# Comparators.
See chapter 3.20.2 LC-1# Comparators.
See chapter 3.20.2 LC-1# Comparators.
See chapter 3.20.2 LC-1# Comparators.
See chapter 3.20.2 LC-1# Comparators.
See chapter 3.20.2 LC-1# Comparators.
See chapter 3.20.2 LC-1# Comparators.
02/2016 All rights reserved.
LC-02 Stop Event
Select the boolean (true or false) input to deactivate Logic
Controller.
Option:
Function:
[0]
False
For descriptions of options [0]
False–[61] Logic rule 5, see
parameter LC-01 Start Event.
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Line voltage out of
range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
Logic Controller
Time-out 0
[31]
Logic Controller
Time-out 1
[32]
Logic Controller
Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
*
[41]
Reset Trip
[42]
Auto-reset Trip