Parameter Descriptions
IO-50 Terminal X49/9 Analogue Output
Select the functionality of terminal X49/9.
Option:
[108]
Torque
[109]
Max Out Freq
[139]
Bus ctrl. 0-20 mA
[141]
Bus ctrl 0-20mA t.o.
IO-52 Terminal X49/9 Min. Scale
Match the minimum output of terminal X49/9 with a required
value. For more information, see parameter IO-42 Terminal X49/7
Min. Scale.
Range:
0 %
[0 - 200 %]
*
IO-53 Terminal X49/9 Max. Scale
Scale the maximum output of terminal X49/9. For more
information, see parameter IO-43 Terminal X49/7 Max. Scale.
Range:
100 %
[0 - 200 %]
*
IO-54 Terminal X49/9 Bus Control
This parameter contains the output level of terminal X49/9 if the
terminal is controlled by a fieldbus.
Range:
0 %
[0 - 100 %]
*
IO-55 Terminal X49/9 Timeout Preset
The frequency converter sends the value of this parameter to the
output terminal when the terminal is controlled by a fieldbus
and a timeout is detected.
Range:
0 %
[0 - 100 %]
*
3.24.7 IO-6# Output X49/11
OPCPRGIO has 3 analog inputs and 3 configurable analog
outputs. Use the parameters in this group to configure the
mode of the analog outputs.
IO-60 Terminal X49/11 Analogue Output
Select the functionality of terminal X49/11.
Option:
[0]
No operation
*
[100]
Output frequency
[101]
Reference
[102]
Feedback
[103]
Motor Current
[104]
Torque rel to limit
[105]
Torq relate to rated
[106]
Power
[107]
Speed
[108]
Torque
[109]
Max Out Freq
DET-618D
AF-650 GP™ Programming Guide
IO-60 Terminal X49/11 Analogue Output
Select the functionality of terminal X49/11.
Function:
Option:
[139]
[141]
IO-62 Terminal X49/11 Min. Scale
Match the minimum output of terminal X49/11 with a required
value. For more information, see parameter IO-42 Terminal X49/7
Min. Scale.
Range:
0 %
Function:
IO-63 Terminal X49/11 Max. Scale
Scale the maximum output of terminal X49/11. For more
information, see parameter IO-43 Terminal X49/7 Max. Scale.
Range:
100 %
Function:
IO-64 Terminal X49/11 Bus Control
This parameter contains the output level of terminal X49/11 if
the terminal is controlled by a fieldbus.
Range:
0 %
Function:
IO-65 Terminal X49/11 Timeout Preset
The frequency converter sends the value of this parameter to the
output terminal when the terminal is controlled by a fieldbus
and a timeout is detected.
Range:
0 %
Function:
Function:
02/2016 All rights reserved.
Bus ctrl. 0-20 mA
Bus ctrl 0-20mA t.o.
[0 - 200 %]
*
[0 - 200 %]
*
[0 - 100 %]
*
[0 - 100 %]
*
Function:
3
Function:
Function:
Function:
Function:
163
3