Figure 9-4. State Logic Processor Module User Details
Status Light
Three Status LEDs exist on the SLP module. The top LED (see figure above) indicates the
condition of the module. It will blink ON and OFF while the module is booting up, then will stay
ON during normal operation. The bottom two LEDs are not used and will always be off.
Pushbutton
See Caution note below before operating the pushbutton. One pushbutton is provided. Pushing
and holding the pushbutton for less than 5 seconds will simply restart the user application program
if it was configured to "auto-run" at power up. Pushing and holding for more than 5 seconds will
reinitialize the module and require that the user application program be reloaded.
9-6
Series 90-30 PLC Installation and Hardware Manual – August 2002
CURRENTLY
INSTALLED
BATTERY
CONNECTOR
OPEN
REPLACEMENT
BATTERY
CONNECTOR
SLP 300
Pushing and holding the pushbutton for more than 5 seconds will reinitialize
the module and require that the user application program be reloaded.
OK
BD OK
RESTART
BATTERY
PORTS
1 AND 2
Caution
GFK-0356Q