User Definable TCP Port Number for RAS

Rev 1.00
Figure 19-2
User Preferences Screen
2.
Set the Remote bandwidth throttle field to the desired bandwidth (1 to 250 KBps).
When you set this field to 250, the RAS User Preferences screen displays Max.
3.
Accept these changes and exit this screen.
Note
The handling of Ethernet LAN TCP/IP data has been modified to allow for
higher bandwidth utilization. Therefore, HRDV16/8 units connected by an
Ethernet LAN have faster image updates per second.
Situation
A customer wants to install multiple HRDV16/8 units behind a common IP
address. The customer's IT department will use TCP port forwarding to accomplish this.
They will assign a different destination TCP port number for each HRDV16/8.
Solution
For RAS to connect to these different HRDV units you must program the different
destination TCP port numbers in the Network Connection dialog box as shown in
Figure
19-4.
139
HRDV Reference Guide
Document 900.0261
04/05