Honeywell HDVR Reference Manual page 197

Table of Contents

Advertisement

Example 3
Line 1
65 32 73 31 74 32 20 30 32 2f 30 34 2f 30 33 20 31 36 3a 34 31 3a 34 31 0a
e
2
s
l
t
2
sp sp 2
Line 2
54 6f 62 61 63 63 6f 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 32 2e 30 30 54 oa
T
o
b
o
c
c
o
Line 3
65 32 73 31 74 32 20 30 32 2f 30 34 2f 30 33 20 31 36 3a 34 32 3a 34 30 0a
e
2
s
l
t
2
sp 0
Line 4
54 72 61 6e 73 61 63 74 69 6f 6e 20 49 44 23 32 35 0a
T
r
a
n
s
a
c
Rev 1.00
POS Server Cash Register Interface With One Specific Start Transaction
Sample trace of POS server data output
Line 1 6532733174322030322F30342F30332031363A34313A34310A
Line 2 546F626163636F202020202020202020202020202020202020322E3030540A
Line 3 6532733174322030322F30342F30332031363A34323A34300A
Line 4 5472616E73616374696F6E2049442332350A
Hexadecimal to ASCII character breakdown
See
Hexadecimal to ASCII
/
0
4
/
0
sp sp sp sp sp sp sp sp sp sp sp sp sp sp sp sp sp sp 2
2
/
0
4
/
0
t
i
o
n
sp I
D # 2
Transaction as it looks on the video monitor
e2slt2 02/04/03 16:41:41
Tobacco
e2slt2 02/04/03
Transaction ID#25
Interpretation of data string
There are no control characters at the beginning or end of each transaction line.
User should de-select the CONTROL CHAR ENABLE button.
There is one specific START transaction.
"Strt Trans Str 1" is "e" and "Strt Trans Str 2" should be disabled.
The cash register number is "2" and it is prefixed by a letter "t".
User should select OR CASHREG PREFIX enabled.
Enable the "End Trans Str" to indicate the end of each transaction. The total of 4
strings (CASE SENSITIVE) can be identified as transaction termination. This helps the
HRDV to stop recording and to store each transaction as a separated video clip. In
this case, the end transaction string is "Transaction."
Conversion, page
181
for a Hex to ASCII conversion chart.
3
sp 1
6
:
4
1
3
sp 1
6
:
4
2
5
lf
2:00T
16:42:40
179
HRDV Reference Guide
:
4
1
lf
.
0
:
4
0
lf
Document 900.0261
0
T
lf
04/05

Advertisement

Table of Contents
loading

Table of Contents