Event Description
Supervisory/Tamper switch
trouble restore
System-based AUX1 switch
alarm
System-based AUX1 switch
alarm restore
System-based AUX1 switch trou-
ble
System-based AUX1 switch trou-
ble restore
System-based AUX2 switch
alarm
System-based AUX2 switch
alarm restore
System-based AUX2 switch trou-
ble
System-based AUX2 switch trou-
ble restore
Voice Aux ECS 1 Alarm
Voice Aux ECS 1 Alarm Restore
Voice Aux ECS 2 Alarm
Voice Aux ECS 2 Alarm Restore
Voice Aux ECS 3 Alarm
Voice Aux ECS 3 Alarm Restore
Voice Aux ECS 4 Alarm
Voice Aux ECS 4 Alarm Restore
Water flow switch alarm
Water flow switch alarm Restore
Water flow switch trouble
Water flow switch trouble Restore
Zone-based AUX1 switch alarm
Zone-based AUX1 switch alarm
restore
Zone-based AUX1 switch trouble
Zone-based AUX1 switch trouble
restore
Zone-based AUX2 switch alarm
Zone-based AUX2 switch alarm
restore
Zone-based AUX2 switch trouble
Zone-based AUX2 switch trouble
restore
165
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter Fixed Length
ID # (If
Event
Any)
Codes
FJ
Zone #
UA
1000
UH
1000
UT
1000
UJ
1000
UA
2000
UH
2000
UT
2000
UJ
2000
UA
3
UH
3
UA
4
UH
4
UA
5
UH
5
UA
6
UH
6
SA
Zone #
SH
Zone #
ST
Zone #
SJ
Zone #
UA
Zone # +
1000
UH
Zone # +
1000
UT
Zone # +
1000
UJ
Zone # +
1000
UA
Zone # +
2000
UH
Zone # +
2000
UT
Zone # +
2000
UJ
Zone # +
2000
Table 12.3 : Report Formats Table
IFP-300 / IFP-300ECS Manual P/N LS10145-001SK-E:B 12/18/2017
Contact ID Reporting Format
SIA
Qualifier
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
FJNN000ZZZ
3
UANN001000
1
UHNN001000
3
UTNN001000
1
UJNN001000
3
UANN002000
1
UHNN002000
3
UTNN002000
1
UJNN002000
3
UANN003000
1
UHNN003000
3
UANN004000
1
UHNN004000
3
UANN005000
1
UHNN005000
3
UANN006000
1
UHNN006000
3
SANN000ZZZ
1
SHNN000ZZZ
3
STNN000ZZZ
1
SJNN000ZZZ
3
UANN001ZZZ
1
UHNN001ZZZ
3
UTNN001ZZZ
1
UJNN001ZZZ
3
UANN002ZZZ
1
UHNN002ZZZ
3
UTNN002ZZZ
1
UJNN002ZZZ
3
Event
Group #
Contact #
Code
373
00
Zone #
140
01
000
140
01
000
373
01
000
373
01
000
140
02
000
140
02
000
373
02
000
373
02
000
171
00
000
171
00
000
172
00
000
172
00
000
173
00
000
173
00
000
174
00
000
174
00
000
113
00
Zone #
113
00
Zone #
373
00
Zone #
373
00
Zone #
140
01
Zone #
140
01
Zone #
373
01
Zone #
373
01
Zone #
140
02
Zone #
140
02
Zone #
373
02
Zone #
373
02
Zone #