State: 0Xb8; State: 0Xc0; State: 0Xc8 - Philips LPC214 Series User Manual

Table of Contents

Advertisement

Philips Semiconductors
Volume 1

11.9.34 State: 0xB8

Data has been transmitted, ACK has been received. Data will be transmitted, ACK bit will
be received.

11.9.35 State: 0xC0

Data has been transmitted, NOT ACK has been received. Not addressed Slave mode is
entered.

11.9.36 State: 0xC8

The last data byte has been transmitted, ACK has been received. Not addressed Slave
mode is entered.
User manual
3. Write 0x08 to I2CONCLR to clear the SI flag.
4. Set up Slave Transmit mode data buffer.
5. Increment Slave Transmit buffer pointer.
6. Exit
1. Load I2DAT from Slave Transmit buffer with data byte.
2. Write 0x04 to I2CONSET to set the AA bit.
3. Write 0x08 to I2CONCLR to clear the SI flag.
4. Increment Slave Transmit buffer pointer.
5. Exit
1. Write 0x04 to I2CONSET to set the AA bit.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit.
1. Write 0x04 to I2CONSET to set the AA bit.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
Rev. 01 — 15 August 2005
UM10139
2
Chapter 11: I
C interfaces
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.