Cyclic data send/receive assurance information
■ Multiple cycle setting (low speed) (Un\G2877442)
The setting value of the multiple cycle setting (low speed) that ensures the cyclic data communications (send/receive) is
stored.
This value is stored when a device station exists for which, under "Basic Settings", "CC-Link IE TSN Class Setting" in
"Connection Device Information" is "CC-Link IE TSN Class A" and "Communication Period Setting" is "Low-Speed".
• 0: Calculation not performed
• 16, 32, 64, 128: Low speed cycle for basic cycle
■ Communication cycle interval (calculation value) (Un\G2877443)
The setting value of the communication cycle interval that ensures the cyclic data communications (send/receive) is stored.
This value is stored when a device station exists for which, under "Basic Settings", "CC-Link IE TSN Class Setting" in
"Connection Device Information" is "CC-Link IE TSN Class A" and "Communication Period Setting" is "Low-Speed".
• 0: Calculation not performed
• 125 to 4294967295: Communication cycle interval (unit: s)
Communication period setting value (protocol version 2.0)
■ Communication cycle interval (calculation value) (Un\G2877444)
Stores the communication cycle interval of "CC-Link IE TSN protocol version 2.0" that are calculated by the number of device
stations and the number of link device points set in "Network Configuration Settings" under "Basic Settings".
• 125 or greater: Communication cycle intervals (unit: s)
■ Cyclic transmission time (calculation value) (Un\G2877445)
Stores the communication cycle interval of "CC-Link IE TSN protocol version 2.0" that are calculated by the number of device
stations and the number of link device points set in "Network Configuration Settings" under "Basic Settings".
• 1 or greater: Cyclic transmission time (unit: s)
■ Transient transmission time (calculation value) (Un\G2877446)
Stores the communication cycle interval of "CC-Link IE TSN protocol version 2.0" that are calculated by the number of device
stations and the number of link device points set in "Network Configuration Settings" under "Basic Settings".
• 1 or greater: Transient transmission time (unit: s)