*2 When using the CC-Link IE TSN Network synchronous communication function, set the same value as "Fixed Scan Interval Setting" of
"Fixed Scan Interval Setting of Inter-module Synchronization" under "Inter-module Synchronization Setting" on the "Inter-module
Synchronization Setting" tab in "System Parameter".
*3 For the version of Add-on baseSystem, "1.4" or earlier, communication cycle is "125.00 s to 4000.00 s".
*4 Can be set only when using RD78GH.
*5 For the version of Add-on baseSystem, "1.4" or earlier, cyclic transmission time is "5.00 s to 3966.00 s".
*6 For the version of Add-on baseSystem, "1.4" or earlier, transient transmission time is "14.00 s to 3975.00 s".
*7 When the version of Add-on baseSystem is "1.18" or earlier, an error occurs if a value other than "16" is set.
• When the TSN hub is used, set the timeslot information from the setting values in "Basic Period Setting".
The timeslot information can be checked with the buffer memory. ( Page 236 Timeslot information)
• Set "Communication Period Setting" according to the communication cycle supported by the device station.
Precautions
• There are device stations which do not correspond to some communication period setting. Check the specifications of each
device.
• When the multiple cycle setting is used, set the cycle so that the calculated value of the communication cycle setting and
the magnification of the multiple cycle setting does not exceed 16 ms. The following are the examples.
• Basic communication cycle 1 ms  Low-speed, 16: Setting allowed
• Basic communication cycle 2 ms  Normal-speed, 8: Setting allowed
• Basic communication cycle 2 ms  Low-speed, 16: Setting disallowed
• When using the PLCopen Motion control FB mode, if there is a standard station in the network configuration setting and the
communication cycle setting is set to less than 125 s, "Standard station communication cycle combination error (error
code: 3228H)" occurs in the Motion module. For details, refer to "List of Error Codes" in the following manual.
MELSEC iQ-R Motion Module User's Manual (Application)
• When using the PLCopen Motion control FB mode and the version of Add-on baseSystem is "1.24" or later, when the
communication mode is set to "multicast" while the communication cycle interval setting is less than 125 s,
"Communication cycle interval setting combination error (error code: 322AH)" occurs.

Connection Device Information

Set the information of the connected device.
Item
*1
CC-Link IE TSN Class Setting
*2
TSN HUB Setting
*1 When this setting is set to "CC-Link IE TSN Class B only", the engineering tool checks whether there is a setting for "CC-Link IE TSN
Class A" in "CC-Link IE TSN Class Setting" of "Network Configuration Settings".
*2 This can be set when "CC-Link IE TSN Class Setting" is set to "Mixture of CC-Link IE TSN Class B/A or CC-Link IE TSN Class A Only".
Precautions
• In the case of "
CC-Link IE TSN
system configuration, different restrictions apply. For details, refer to "SYSTEM CONFIGURATION" (in the chapter of the
control mode used) of the following manual.
MELSEC iQ-R Motion Module User's Manual (Startup)
• To connect a TSN hub when "
Class A Only", set "TSN HUB Setting" to "Use TSN HUB".
Description
Set the CC-Link IE TSN Class of connected devices.
Set whether to use a TSN hub.
Class B Only" and "Mixture of
Class Setting" is set to "Mixture of
CC-Link IE TSN
Setting range
• CC-Link IE TSN Class B only
• Mixture of CC-Link IE TSN Class B/A or Authentication Class A
Only
(Default:CC-Link IE TSN Class B only)
• Not to Use TSN HUB
• Use TSN HUB
(Default: Not to Use TSN HUB)
Class B/A or
CC-Link IE TSN
CC-Link IE TSN
CC-Link IE TSN
Class A Only"
Class B/A or
CC-Link IE TSN