No.
Name
SW0470 to
NMT state machine
SW047F
SW04A0
Time synchronization
method
SW04B0
Time synchronization
to
status of each station
SW04B7
SW04C0
Driver
communication cycle
interval
SW04C1
Driver
communication cycle
system reservation
time
SW04C2
Driver
communication cycle
cyclic transmission
time
SW04C3
Driver
communication cycle
transient
transmission time
SW04C4
Driver
communication
magnification (basic)
SW04C5
Driver
communication
magnification
(medium-speed)
SW04C6
Driver
communication
magnification (low-
speed)
Description
Stores the communication status of the device station that supports CANopen
communications.
0: In the CANopen function initialization sequence, the NMT state machine is not yet in
the Operational state or the device station is disconnected.
1: In the CANopen function initialization sequence, the NMT state machine is in the
Operational state.
The value of the device station that does not support CANopen communications is fixed
to 0.
This value is stored by each module number of the device stations set in the network
configuration setting.
Stores the synchronization method.
0: IEEE 1588
1: IEEE 802.1AS
Stores the time synchronization status of each station. (Station number: 1 to 120)
0: Station that does not perform time synchronization
1: Station that performs time synchronization
The time synchronization method can be checked in 'Time synchronization method'
(SW04A0).
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW04B0
16 15 14 13 12 11 10
SW04B1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW04B2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW04B3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW04B4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW04B5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW04B6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW04B7
Each No. in the table represents a station No.
 is fixed to 0.
(Conditions)
• Stations that surpass the maximum station No are ignored.
Stores the driver communication cycle currently operating. (Unit: s)
Fixed to 0 when driver communication is disabled.
Stores the system reservation time in 'Driver communication cycle interval' (SW04C0).
(Unit: s)
Fixed to 0 when driver communication is disabled.
Stores the cyclic transmission time in 'Driver communication cycle interval' (SW04C0).
(Unit: s)
Fixed to 0 when driver communication is disabled.
Stores the transient transmission time in 'Driver communication cycle interval' (SW04C0).
(Unit: s)
Fixed to 0 when driver communication is disabled.
Stores the magnification of the basic communication cycle conversion based on 'Driver
communication cycle interval' (SW04C0).
Fixed to 0 when driver communication is disabled.
Stores the magnification of the multiple cycle setting (medium-speed) conversion based
on 'Driver communication cycle interval' (SW04C0).
Fixed to 0 when driver communication is disabled.
Stores the magnification of the multiple cycle setting (low-speed) conversion based on
'Driver communication cycle interval' (SW04C0).
Fixed to 0 when driver communication is disabled.
9
8
7
6
5
4
3
2
1
120 119 118 117 116 115 114 113
Appendix 4 List of Link Special Register (SW)
Availability
PLCopen
Simple
Motion
Motion
control FB
mode
mode
APPX
263
A