display
display
Cyclic Transmission Time
The cyclic transmission time that are calculated by the number of device stations
(Min.)
and the number of link device points is displayed. Use the displayed value as a
*1*13
guide.
Even if the number of device stations and link device points are the same, the
displayed values differ depending on "TSN HUB Setting" of "Connection Device
Information" under "Basic Settings". For details, refer to the following.
Page 275 Communication cycle interval
The displayed value can be used for "Cyclic Transmission Time" in
"Communication Period Setting" under "Basic Settings" of the module parameter.
If cyclic transmission is not performed by setting the displayed value, set a value
obtained by adding 10% as follows.
• 10% of the minimum value of the calculated cyclic transmission time
• When the communication speed for the master station is set to 1 Gbps: The
number of device stations  2 s
• When the communication speed for the master station is set to 100 Mbps: The
number of device stations  20 s
When the communication speed of the master station is 1 Gbps in unicast mode
or multicast mode with version "1.085P" or earlier of the engineering tool (if a CC-
Link IE TSN Class A device station with the basic cycle or normal speed cycle
exists), the time cannot be checked. Check it with 'Cyclic transmission time
(calculation value)' (SW0073).
Page 254 List of link special register (SW)
Communication Period
The communication cycle intervals that are calculated by the number of device
*2
Interval (Min.)
stations and the number of link device points are displayed. Use the displayed
value as a guide.
Even if the number of device stations and link device points are the same, the
displayed values differ depending on "TSN HUB Setting" of "Connection Device
Information" under "Basic Settings". For details, refer to the following.
Page 275 Communication cycle interval
The displayed value can be used for "Communication Period Interval Setting" in
"Communication Period Setting" under "Basic Settings" of the module parameter.
If cyclic transmission is not performed by configuring the setting with the
displayed value, set a value obtained by adding 10% as follows.
Calculation formula: B + A  0.1
A: Cyclic transmission time (minimum value)
B: Communication cycle interval (minimum value)
When the communication speed of the master station is 1 Gbps in unicast mode
or multicast mode with version "1.085P" or earlier of the engineering tool (if a CC-
Link IE TSN Class A device station with the basic cycle or normal speed cycle
exists), the interval cannot be checked. Check it with 'Communication cycle
interval (calculation value)' (SW0072).
Page 254 List of link special register (SW)
No.
The total number of device stations set in the "CC-Link IE TSN Configuration"
window is displayed.
Model Name
The module model name is displayed.
To set a module where the profile is not registered, select it from the "General
CC-Link IE TSN Module" list or register the profile before setting the model name.
For how to register a profile, refer to the following.
 GX Works3 Operating Manual
STA#
Enter the station No. of each device station connected to the network.
Station numbers do not need to be set consecutively, but must be unique.
*4
Station Type
Set the station types. Select the station types same as those of the modules
connected to the network.
*5
Motion Control Station
Use the profile to allow selection of target stations for motion control.
RX Setting
Assign RX/RY points in increments of 16. ( Page 20 Communications using
RX, RY, RWr, and RWw)
RY Setting
Modules with settings provided by the device profile are automatically set from
selected models. (Excluding modules with a number of points that is not fixed)
For the motion control station, only the number of points is set.
■When the GX Works3 is version "1.085P" or later
<When using PLCopen Motion control FB mode>
• For the motion control station, only the number of points is set.
<When using Simple Motion mode>
• For the motion control station, settings cannot be made.
*1*13
Setting range
• Master station: Fixed to "0"
• Device station: 1 to 256
• Master station: Fixed to "0"
*3
• Device station: 1 to 120
(Default: Serial No. of added stations)
*14
• Local station
• Remote Station
(Default: Varies depending on the set module)
• Checked: Motion control target
• Not checked: Not motion control target
(Default: Checked)
• Number of points: No point, 16 to 16384
• Start: 0000H to 3FF0H
• End: 000FH to 3FFFH
(Default: Varies depending on the set module)
2 PARAMETER SETTINGS
2.5 "CC-Link IE TSN Configuration" Window
2
*6
*6
113