Mitsubishi Electric MELSEC iQ-R Series User Manual page 108

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
Setting Method
No.
Communication Destination
Network
Network No.
Configuration
Station No.
IP Address
Station Type
Configured Module
Model Name
Communication
Destination
PLC No.
Open System
Sending Interval Monitoring Time [ms]
Safety Refresh Monitoring Time [ms]
2 PARAMETER SETTINGS
106
2.3 Basic Settings
Description
Right-click in the "Safety Communication Setting" window and
select an assignment method in "Safety Data Transfer Device
Setting".
• Start/End: Enter the start and end numbers of safety devices.
• Points/Start: Enter the points and start numbers of safety
devices.
Safety connection number for distinguishing settings for each
safety connection.
Set a network of the communication destination.
The network number of the communication destination is
displayed.
The station number of communication destination selected in the
"Select the target module for the Safety Communication Setting"
window is displayed.
*3
The IP address of communication destination selected in the
"Select the target module for the Safety Communication Setting"
window is displayed.
The station type of the communication destination selected in
the "Select the target module for the Safety Communication
Setting" window is displayed.
The module model name of the communication destination
selected in the "Select the target module for the Safety
Communication Setting" window is displayed. (Only device
station other than the local station)
When the communication destination is a local station: Set the
CPU model name of communication destination.
Set the CPU number of the communication destination when the
CPU module of the communication destination is set to CPU
module other than the Safety CPU.
Open system of the own station is displayed.
In each safety connection, set sending interval monitoring time
for a receiving station to detect safety communication errors.
In each safety connection, set safety refresh monitoring time for
a receiving station to detect safety communication errors.
Setting range
• Start/End
• Points/Start
(Default: Start/End)
*2
1 to 120
Local Network
(Default: empty)
0.0.0.1 to 223.255.255.254
(Default: empty)
• Local station
• Remote station
(Default: empty)
• R08SFCPU
• R16SFCPU
• R32SFCPU
• R120SFCPU
• R16NCCPU
(Default: empty)
2 to 4
(Default: empty)
Active (Fixed)
(Default: empty)
3.0 to 1000.0
(Default: empty)
4.0 to 2000.0
(Default: empty)