Own station information
The information of the own station on the network is stored.
■ Own station (network card) information (Un\G2852096 to Un\G2852103)
Address
Un\G2852096
Un\G2852097
Un\G2852098
Un\G2852099
Un\G2852100
Un\G2852101 to Un\G2852103
■ Own station (controller) information (Un\G2852104 to Un\G2852121)
Address
Un\G2852104
Un\G2852105
Un\G2852106
Un\G2852107
Un\G2852108
Un\G2852109
Un\G2852110 to Un\G2852119
Un\G2852120 to Un\G2852121
Communication path determination status
■ Communication path determination status (Un\G2860544 to Un\G2860559)
The determination information on the communication path for each network number of the destination station is stored.
• 0: Path undetermined
• 1: Path determined
Address
b15
b14
Un\G2860544
16
15
Un\G2860558
Empty
239
Un\G2860559
Empty
The numbers in the table indicate network Nos.
Time synchronization
■ Time distribution interval setting of the CPU module (Un\G2875136)
The time distribution interval of the CPU module on the master station to device stations is set (CPU number 1 when the
multiple CPU system is used). This setting is set to the buffer memory of the master station.
When the setting is changed, the new setting value is enabled after the interval of the distribution operating with the old setting
value has elapsed. The setting value is distributed once after the distribution interval elapses. If the new setting value needs to
be enabled immediately, stop the distribution and set the value.
• 0000H: 10 s
• 0001H to FFFEH: (Send using the set time interval (second))
• FFFFH: (Distribution stop)
(Default: 0000H)
Name
Manufacturer code
Model type
Model code (lower 2 bytes)
Model code (upper 2 bytes)
Version
MAC address
Name
Controller information valid/invalid flag
Manufacturer code
Model type
Model code (lower 2 bytes)
Model code (upper 2 bytes)
Version
Model name string
Vendor-specific device information
b13
b12
b11
b10
b9
14
13
12
11
10
238
237
236
235
234
Description
The information of the own station is stored.
(Also used in the CLPA conformance test.)
(Updated even when the station is set to the error invalid station.)
(Updated even when the station is set to the reserved station.)
The own station MAC address is stored.
Un\G2852101: 5th byte, 6th byte of the MAC address
Un\G2852102: 3rd byte, 4th byte of the MAC address
Un\G2852103: 1st byte, 2nd byte of the MAC address
Description
Whether the value stored in the own station (controller) information
is valid or invalid is stored.
• 0: Invalid
• 1: Valid
The information of the own station is stored.
b8
b7
b6
b5
9
8
7
6
233
232
231
230
Appendix 2 Buffer Memory (When Using the Simple Motion Mode)
b4
b3
b2
b1
b0
5
4
3
2
1
229
228
227
226
225
APPX
A
239

Advertisement