Name of variable
Description
ndm
((Total number of points of "RY Setting" of main modules) / 8) + ((Total number of points of "RWw Setting" of main modules)  2) +
((Number of points of "LB setting" set in the master station) / 8)  ((Number of points of "LW setting" set in the master station)  2)  Ln
sndm
Number of connections in "Safety Communication Setting" in "Basic Settings" of the master station  80
Sn
Number of device stations
SSn
Number of device stations using safety communications
Ln
Number of local stations
nh
Switching hub delay time  Number of switching hubs connected to the network
Switching hub delay time: 50000
nrp
When "Network Topology" under " Basic Settings" is set to " Line/Star": 0
n3
Sn  nhs
nhs: Value of (nds + (20  n4)) / (1488  Sn) rounded up to the nearest integer
n4
Sn  (RXb + RWrb) + Ln  (LBxmb + LWxmb) + Sn
RXb: Value of (Total number of points of "RX Setting" of main modules) / (11744  Sn) rounded up to the nearest integer
RWrb: Value of (Total number of points of "RWr Setting" of main modules) / (734  Sn) rounded up to the nearest integer
LBxmb: Value of (Total number of points of "LB setting" excluding master station) / (11744  Ln) rounded up to the nearest integer
LWxmb: Value of (Total number of points of "LW setting" excluding master station) / (734  Ln) rounded up to the nearest integer
nds
((Total number of points of "RX setting" of main modules) / 8) + ((Total number of points of "RWr setting" of main modules)  2) + ((Total
number of points of "LB setting" excluding the master station) / 8) + ((Total number of points of "LW setting" excluding the master
station)  2) + 8  Sn
n5
(ndl + 20  n6) / 1488
n6
(ndl - 8) / 1468 + 1
ndl
(RXl / 8) + (RWrl  2) + (LBl / 8) + (LWl  2) + 8
RXl: Number of points of "RX Setting" of the main module of the device station
RWrl: Number of points of "RWr Setting" of the main module of the device station
LBl: Number of points of "LB setting" of the device station
LWl: Number of points of "LW setting" of the device station
n7
When "CC-Link IE TSN Class Setting" is set to "Mixture of CC-Link IE TSN Class B / A or CC-Link IE TSN Class A Only" and "TSN
HUB Setting" is set to "Not to Use TSN HUB": 4
Other than the above: 0
en1
en1
However, if endm
k
mf
However, if the calculation result of mf
en2
en2
However, if endm
endm
endm
APPX
278
Appendix 6 Processing Time
*1
6
120
en1
i
i = 1
= ((endm
+ en2
 16) / 1488)
i
i
i
is 0, en1
becomes 0.
i
i
= 1 if mf
> 16, k
= 0 if mf
 16
i
i
i
i
= 1488 - mod
i
mod: Remainder of {((mRy
+ (mRy
i
i: Station number
mRy
: Number of points of "RY Setting" of the main module of the station number i / 8
i
mRWw
: Number of points of "RWw Setting" of the main module of the station number i  2
i
6
120
en2
i
i = 1
= eRyn
+ eRWwn
+ ((endm
+ (eRyn
i
i
i
i
is 0, en2
becomes 0.
i
i
i: Station number
eRyn
: 0 (fixed)
i
eRWwn
: Total number of extension modules which have a number of points of "RWw Setting" of the station number i larger than 0
i
6
120
endm
i
i = 1
= eRyAll
/ 8 + eRWwAll
 2
i
i
i
i: Station number
eRyAll
: 0 (fixed)
i
eRWwAll
: Total number of points of "RWw Setting" of the extension modules of the station number i
i
*2
to be used as the maximum number of link points
*2
to be used as the maximum number of link points
*3
- k
i
*3
/ 1472)
 16) + (mRWw
+ (mRWw
i
i
is 1488, this value becomes 0.
i
*3
+ eRWwn
)  16) / 1488)
i
i
*2
to be used as the maximum number of link points
*2
to be used as the maximum number of link points
*3
/ 1472)
 16)) / 1488}
i
- 1