Applicable device
The following table shows the devices that can be synchronized by the CC-Link IE TSN Network synchronous communication
function.
: Synchronizable, : Not synchronizable
CC-Link IE TSN Network
CC-Link IE TSN Class
synchronous
communication function
Not supported
Supported
CC-Link IE TSN Class A
device
CC-Link IE TSN Class B
device
■ Setting for a station not synchronizable
• When the network synchronous communication setting is set for a device station that is not synchronizable, Initialization
failure (parameter mismatch between master and device stations) (event code: 00C71) is displayed in the event history in
the master station. (Network synchronous communication and cyclic transmission with other device stations are continued.)
• In the local station for which "Network Synchronous Communication" in "Network Configuration Settings" under "Basic
Settings" of the master station is set to "Synchronous", if "Select Inter-module Synchronization Target Module" in "System
Parameter" on the local station side is set to "Asynchronous", "Inter-module synchronization target mismatch (error code:
3601H)" occurs.
Communication speed
Communication cycle
setting
1 Gbps
Basic cycle
Normal-Speed
Low-Speed
100 Mbps
Basic cycle
Normal-Speed
Low-Speed
1.6 CC-Link IE TSN Network Synchronous Communication Function
1
Synchronization
1 FUNCTIONS
81