5.5 Relay and fieldbus interfaces
Connection
The wired RJ45 connectors are connected to the two X1000 Port 1 and X1000 Port 2 terminals.
5.5.3.3

Wiring and connecting relay outputs

Wiring
The PROFINET module has 2 relay outputs (closer contact).
A maximum voltage of 42.0 V (SELV according to EN60950-1) may be applied to the PROFINET
module.
Contact rating of the relay outputs:
• DC max: 30 V DC, 500 mA
The matching 4-pole mating connector (PHOENIX MC1.5/4-ST-3.81) with the screw terminals is
delivered along with the module (plugged in).
The pin assignments are:
X100.1
X100.2
X100.3
X100.4