If the reversing device is switched off, the maximum kinetic energy must not exceed 4 joules.
W
KIN
Example from the following speed limit curve:
• Moved mass m = 180 kg => v
Figure 4-4
Adjustment ranges
You can find the adjustment ranges in section Profiles and adjustment ranges (Page 329).
Maximum speeds
The following table shows the maximum speeds depending on moved weight and energy limit:
Table 4-10
Weight to
be moved
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
=
1/2
m ∙ v² = 4 J.
Speed limit curve for W
Maximum speeds [mm/s] as a function of moving mass and energy limit
4
[kg]
50
400
100
283
150
231
200
200
250
179
300
163
350
151
400
141
450
133
500
126
= 0.21 m / s.
max
=4J
KIN
Energy [J]
10
25
632
1000
447
707
365
577
316
500
283
447
258
408
239
378
224
354
211
333
200
316
SIDOOR functions
4.2 System functions
50
75
1414
1732
1000
1225
816
1000
707
866
632
775
577
707
535
655
500
612
471
577
447
548
100
2000
1414
1155
1000
894
816
756
707
667
632
75