Siemens SIDOOR ATD4 W Series System Manual page 175

Automatic door control units
Table of Contents

Advertisement

Article number
Active power input (standby
mode)
Digital inputs
Control inputs isolated
Control inputs p-switching
Input voltage
Input current
Digital outputs
Relay outputs
Switching capacity of contacts
Mechanical data
Opening width of door, min.
Opening width of door, max.
Weight of door, max.
Operating cycle frequency of
door, max.
Counterforce, max.
Kinetic energy, max.
Interfaces
Interfaces/bus type
Number of bus nodes
Isolation
Overvoltage category
Degree of pollution
Degree and class of protection
IP degree of protection
Standards, approvals, certifi‐
cates
Certificate of suitability accord‐
ing to EN 81
CE mark
UL approval
EAC (formerly Gost-R)
TÜV Inspectorate approval
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
permissible voltage at in‐
put, min.
permissible voltage at in‐
put, max.
for signal "1", min.
for signal "1", max.
– at 30 V DC, min.
– at 30 V DC, max.
6FB1141-1AT11-3W
6FB1141-2AT10-3W
E2
E2
5 W
Yes
Yes
10 V; Observe polarity !
28 V; Observe polarity !
9 mA
27 mA
0.01 A
1 A
0.5 A
0.3 m
5 m
600 kg
180 1/h
75 N
100 J
without
PROFIBUS according
to IEC 61784-3
32
2
2
IP20
No
Yes
Yes
Yes
Yes
Controllers
5.8 Technical specifications
6FB1141-3AT10-3W
E2
PROFINET IO accord‐
ing to Conformance
Class C
173