Siemens SIDOOR ATD4 W Series System Manual page 201

Automatic door control units
Table of Contents

Advertisement

Parameter
Name
ID
p20003
DCMD_DI1_Q5
p20004
DCMD_DI1_Q6
p20005
DCMD_DI1_Q7
p20006
DCMD_DI2_Q8
p20007
DCMD_DI2_Q9
p20008
DCMD_DI2_Q10
p20009
DCMD_DI3_Q11
p20010
DCMD_DI3_Q12
p20011
DCMD_DI3_Q13
p20012
DCMD_DI4_Q14
p20013
DCMD_DI4_Q15
p20014
DCMD_DI4_Q16
p20031
DCMD_DI0_39
p20032
DCMD_DI1_40
p20033
DCMD_DI2_41
p20034
DCMD_DI3_42
p20035
DCMD_DI4_43
Control bits (as of V1.10)
p20036
DCMD_SBIT0_Q44
p20037
DCMD_SBIT0_Q45
p20038
DCMD_SBIT0_Q46
p20040
DCMD_SBIT1_Q48
p20041
DCMD_SBIT1_Q49
p20042
DCMD_SBIT1_Q50
p20044
DCMD_SBIT2_Q52
p20045
DCMD_SBIT2_Q53
p20046
DCMD_SBIT2_Q54
p20048
DCMD_SBIT3_Q56
p20049
DCMD_SBIT3_Q57
p20050
DCMD_SBIT3_Q58
p20052
DCMD_SBIT4_Q60
p20053
DCMD_SBIT4_Q61
p20054
DCMD_SBIT4_Q62
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
Description
Rising (positive) edge
Falling (negative) edge
Level-controlled output; output follows the input directly
Rising (positive) edge
Falling (negative) edge
Level-controlled output; output follows the input directly
Rising (positive) edge
Falling (negative) edge
Level-controlled output; output follows the input directly
Rising (positive) edge
Falling (negative) edge
Level-controlled output; output follows the input directly
Level-controlled output; output follows the input inverted
(firmware version 1.03 or higher)
Rising (positive) edge
Falling (negative) edge
Level-controlled output, output follows the input directly
Rising (positive) edge
Falling (negative) edge
Level-controlled output, output follows the input directly
Rising (positive) edge
Falling (negative) edge
Level-controlled output, output follows the input directly
Rising (positive) edge
Falling (negative) edge
Level-controlled output, output follows the input directly
Rising (positive) edge
Falling (negative) edge
Level-controlled output, output follows the input directly
5.9 Operation and configuration of the control unit
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Output is active for one cycle when input edge is detected.
The entered drive order (DCMD) is automatically latched
(stored).
Controllers
199