SIDOOR functions
4.3 Extended functions
The main functions in this context are:
• The inputs "Cord-operated switch", "Close pushbutton" and "Open pushbutton" are pulse
inputs, which means a positive edge at the input signal triggers a drive command.
• With the "Input RC" input the motor can be switched de-energized (for example at a locked
door)
• Automatic closing of the door after parameterizable times
• With the input "Cord operated switch" the door can be alternatingly opened or closed. A
special drive command (e. g partial opening) can be parameterized for the opening with a
cord operated switch.
Note
Although the RC input is activated, it is possible to move the door using the service buttons.
SIDOOR ATD401W:
For the ATD401W there is a special menu command available for activating the cold storage
functions (see section Navigation structure in the SIDOOR SERVICE TOOL (Page 274) and section
Digital input signals (Page 132)).
When the menu item "FBLOCK config. Cold storage mode" is selected, the existing FBLOCK logic
is deleted and the parameterization is preset with the values described in the table below. For
the commissioning of a cold storage door further settings are required. These are described in
the section Operation as cold storage door (Page 110).
Parameter
Value
FBLOCK cold storage door
p20127
4
p20129
10
p20130
13
p20131
16
p20057
512
p20058
528
p20059
768
p20060
256
p1250
6
p1251
0
p1252
3000
FBLOCK Position block
p20061
32
p2200
0
p2201
10
p2202
0
p2203
0
104
Unit
Description
-
Logic operation input "RC input" with digital input "DI0"
-
Logic operation input "Cord-operated switch" with digital input
"DI2"
-
Logic operation input "CLOSE switch" with digital input "DI3"
-
Logic operation input "OPEN switch" with digital input "DI4"
-
Logic operation output "Open" with DCMD drive command "Open"
-
Logic operation output "Cord-operated switch open" with DCMD
drive command "Partial opening"
-
Logic operation output "Close" with DCMD drive command "Close"
-
Logic operation output "Stop" with DCMD drive command "Stop"
s
OPEN switch: Automatic closing after 6 seconds
s
Cord-operated switch: No automatic closing
ms
Close command remains applied 3 seconds in closed position
-
Switchover to "Specific door range of motion"
cm
Normal operation: Start position in open direction
cm
Normal operation: Width in opening direction
cm
Normal operation: Start position in close direction (is not used here)
cm
Normal operation: Width in close direction (is not used here)
ATD4xxW for industrial applications