Controllers
5.5 Relay and fieldbus interfaces
When the device is used for the first time, it has the pre-configured IP address 192.168.0.1
(subnet mask 255.255.255.0).
Note
If reset to the factory defaults, the pre-configured IP address is deleted and set to 0.0.0.0. If the
IP address is assigned by the IO controller based on the system configuration, the retentively
stored IP address is deleted and is replaced with 0.0.0.0 in accordance with the PROFINET
standard.
Identification flashing
Identification is performed via flash test. The flash test can be initiated via the configuration tool.
The two LINK LEDs H1011 (Port1) and H1021 (Port2) flash synchronously, at a frequency of 2 Hz.
Restore factory settings
The "Restore factory settings" function clears the previously defined settings and restores the
default values.
• IP Address: 0.0.0.0
• Device name: (empty)
The I&M data 1 to 4 are additionally cleared when the factory settings are restored.
MAC addresses
The ATD430W IO device uses a total of three MAC addresses. The IO device itself has one MAC
address and the two ports (Port 1, Port 2) each have an incremented MAC address. See the
following example:
IO device: 00-1B-1B-65-AC-61
Port 1:
Port 2:
Supported PROFINET functionality
The ATD430W IO device supports the following functionality of conformance classes A, B and C
(CC-A, CC-B, CC-C).
• Cyclic data exchange (RT)
• Acyclic parameter data (read / write record)
• Device diagnostics, alarms (alarm handling)
• Device identification (I&M 0)
• Extended device identification (I&M 1 to 4)
• Topology information (LLDP)
• Network diagnostics (SNMP)
152
00-1B-1B-65-AC-62
00-1B-1B-65-AC-63
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA