Siemens SIDOOR ATD4 W Series System Manual page 80

Automatic door control units
Table of Contents

Advertisement

SIDOOR functions
4.2 System functions
The respective checksums can also be read out via the service menu.
Parameter
p90
p91
p92
p93
p95
p100
r200 – r202
p1200 – p1242
p1250 – p1252
p2020 – p2023
p2040
p2080 – p2081
p2101 – p2111
p2200 – p2205
p3660 – p3685
p3686 – p3689
p3850 – p3885
p4600
p4601
p4602
p4610 – p4611
p4700 – p4702
p20000 – p20030
p20057 – p20060
p20100 – p20122
p20127 – p20130
Validity of checksums
If parameters were changed and not yet stored retentively, parameter r204 returns the value 0
(checksum invalid) and the parameter checksums r200 and r201 also have the value 0.
When the retentive storage of the parameters is finished, parameter r204 returns the value 1 and
the parameter checksums r200 and r201 have a value unequal to 0.
78
Meaning
Write protection
Reset to factory settings
Reset FBLOCK parameter set to factory settings (com‐
mand parameters)
Load factory settings of the driving curve parameter set
Activation of a test run
Default command mode
Checksums/change counters of the parameters (ReadOn‐
ly) (new)
Calibration and function parameters
Calibration and function parameters for old calibration
functions
Fieldbus communication channel parameters
Fieldbus monitoring time for the master monitoring
DCMD fieldbus/ext.DCMD filter
Calibration and function parameters - basic parameters
Parameters for position block
Driving parameters
Parameters for reduced door range of motion
Obstruction and reversing parameters
Local sensor type
Discrepancy time in the function test of the OSSD system Yes
Output transmission
Discrepancy analysis times (AND0 and AND2)
Fieldbus value selection for cyclic transfer of process val‐
ues
FBLOCK DCMD
FBLOCK DCMD for old calibration functions
FBLOCK REF
FBLOCK REF for old calibration functions
Included in
Included in
default
learn run
checksum
checksum
(r200)
(r201)
No
No
Yes
Yes
No
No
No
No
No
No
Yes
No
No
No
Yes
No
Yes
No
No
No
Yes
No
Yes
No
No
Yes
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
No
No
Yes
No
Yes
No
Yes
No
Yes
No
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
Change
counter
default
parame‐
ter
(r202)
+1
Set to "0"
0
+1
0
+1
0
+1
+1
0
+1
+1
0
+1
+1
+1
+1
+1
+1
+1
+1
0
+1
+1
+1
+1