Controllers
5.9 Operation and configuration of the control unit
Parameter
Name
ID
p20039
DCMD_SBIT0_Q47
p20043
DCMD_SBIT1_Q51
p20047
DCMD_SBIT2_Q55
p20051
DCMD_SBIT3_Q59
p20055
DCMD_SBIT4_Q63
AND
p20015
DCMD_AND0_Q17
p20016
DCMD_AND1_Q18
(As of V1.10)
p20056
DCMD_AND2_Q64
OR
p20017
DCMD_OR0_Q19
p20018
DCMD_OR1_Q20
NOT
p20019
DCMD_NOT0_Q21
p20020
DCMD_NOT1_Q22
XOR
p20021
DCMD_XOR0_Q23
FRQ
p20022
DCMD_FRQ0_Q24
p20023
DCMD_FRQ0_Q25
p20024
DCMD_FRQ1_Q26
p20025
DCMD_FRQ1_Q27
DELAY
p20026
DCMD_OnDELAY_Q28
p20027
DCMD_OnDELAY_Q29
COUNTER
p20028
DCMD_COUNTER_Q30
p20029
DCMD_COUNTER_Q31
p20030
DCMD_COUNTER_Q32
COLD-STORAGE FUNCTION (as of V1.12)
p20057
DCMD_CSR_Q65
p20058
DCMD_CSR_Q66
p20059
DCMD_CSR_Q67
p20060
DCMD_CSR_Q68
200
Description
Level-controlled output; output follows the input inverted
Output is logically ANDed with inputs. a discrepancy analysis of the inputs can be
additionally activated.
Output is logically AND-combined with inputs.
Output is logically ANDed with inputs. a discrepancy analysis of the inputs can be
additionally activated.
Output is logically OR-combined with inputs.
Output is logically NOT-combined with inputs (negation).
Output is logically exclusively OR-combined with inputs.
Output becomes active as soon as the frequency is detected.
Output follows positive input signal delayed by the set delay time.
Output is active as long as the counter value is 0.
Output is active as long as the counter value is 1.
Output is active as long as the counter value is 2.
Output is active as long as the cold storage FBLOCK applies the open signal (see cold
storage function block (as of V1.12)). Replace with "function block" here and in the
following block).
Output is active as long as the cold storage FBLOCK applies the cord-operated switch
open signal (see Cold storage function block (as of V1.12) (Page 103)).
Output is active as long as the cold storage FBLOCK applies the open signal (see Cold
storage function block (as of V1.12) (Page 103)).
Output is active as long as the cold storage FBLOCK applies the stop signal (see Cold
storage function block (as of V1.12) (Page 103)).
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA