System Control Data - Mitsubishi Electric MELSEC Q Series User Manual

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

6 DATA USED FOR POSITIONING CONTROL

6.6.2 System control data

Buffer
Symbol
memory
address
Flash ROM write
5000
Cd.100
request
Parameter initialization
5001
Cd.101
request
(Note-1): Cycle of processing executed at free time except the positioning control. It changes by status of axis start.
(1) System control data
Items
Write the contents (Basic
parameters, OPR parameters,
Manual control parameters, System
parameters, Positioning data and
servo parameters) from the buffer
memory to the flash ROM.
Execute the parameter (Basic
parameters, OPR parameters,
Manual control parameters, System
parameters, Positioning data and
servo parameters) initialization
request stored in the flash ROM.
(Note): Initialization
The setting data can be
returned to the factory
default.
Details
0: Not requested
1: Requested
(Note): "0" can be
0: Not requested
1: Requested
(Note): "0" can be
6 - 39
Setting range
Fetch timing
automatically
stored after the
writing
completion.
Main cycle
(Note-1)
automatically
stored after the
initialization
completion. (Also,
"0" can be stored
at the initialization
error occurrence.)
MELSEC-Q
Factory
default
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd74mh

Table of Contents