Mitsubishi Electric MELSEC Q Series User Manual page 25

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

1 OVERVIEW
Communication
Control signals
Write data
Status signal
Read data
Communication
Control signals of SSCNET
Status signals of SSCNET
Communication
Forced stop input signal
(1) QD74MH ― PLC CPU
The QD74MH and PLC CPU communicate the following data via the base unit.
Signal related to commands
• Y0: PLC READY signal
• Y1: All axis servo ON signals
• Y2: Stop signals
• Y10 to Y1F: Positioning start signals
Data to be written to buffer memory
• Parameter
(Basic, OPR, Manual control, System, Servo)
• Control data
• Positioning data
Signal indicating QD74MH state
• X0: Unit READY signal
• X1: Error detection signal
• X2: Warning detection signal
• X2: Synchronization flag signal
• X10 to X1F: Busy signal
Data to be read from buffer memory
• Parameters
(Basic, OPR, Manual control, System, Servo)
• Monitor data
• Control data
• Positioning data
(2) QD74MH ― Servo amplifier
The QD74MH and servo amplifier communicate the following data via the
SSCNET
.
Command signals to servo amplifier
• Position commands
• Control commands
• Servo parameters
Monitor information of the servo amplifier
• Operating information of the servo amplifier
• Servo parameters (Auto tuning, Parameter
change by MR Configurator, etc.,)
• External input signals (DOG, FLS, RLS) of the
servo amplifier
(3) QD74MH ― Forced stop input signal
The QD74MH and forced stop input signal communicate the following data via
the forced stop input connector.
Forced stop input signal to QD74MH
Details
Details
Details
1 - 6
MELSEC-Q
Signal direction
PLC CPU
QD74MH
QD74MH
PLC CPU
Signal direction
QD74MH
Servo amplifier
Servo amplifier
QD74MH
Signal direction
Forced stop input
QD74MH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd74mh

Table of Contents