5. Position the manual tube to the cover bracket. Install
2 screws securing the manual tube assembly to the
control panel and control bracket (Fig. 1496).
6. Slide the fuse block(s) onto the control panel cover
bracket (Fig. 1497).
7. Connect the negative battery cable to the battery.
9
9-34
Fig 1496
PICT-1839
Fig 1497
PICT-1836
Operator Presence Control (OPC)
Switch Replacement (Pistol Grip)
Note: The harness has been unplugged from the
PTO switch for photo purposes.
OPC Switch Removal (P.G.)
1. Turn the engine off and remove the key from the
ignition.
2. Disconnect the negative battery cable from the
battery.
3. Remove the fuse blocks from the control panel cover
bracket (Fig. 1498).
Fig 1498