General; Using The Product Manual - ABB i-bus KNX Product Manual

Energy actuator se/s 3.16.1
Hide thumbs Also See for i-bus KNX:
Table of Contents

Advertisement

ABB i-bus
KNX

General

1
General
With the intelligent power grids of tomorrow – the Smart Grids – electrical building installations will be fac-
ing new challenges. In order to increase the energy efficiency of buildings and at the same time integrate
the consumers in the load compensation, it is necessary to switch electrical devices in buildings based on
external signals such as time, consumption thresholds or similar. The ABB i-bus
mum prerequisites for intelligent buildings.
By combining energy management with illumination and shutter control, heating, ventilation and surveil-
lance, the use of the ABB i-bus
combined with cost-effectiveness and environmental awareness with minimal planning and installation ef-
fort. Furthermore, the flexible usage of rooms and the continuous adaptation to changing requirements are
simple to realise.
The ABB i-bus
sumption of the connected electrical loads.
The active energy consumption per switching output is determined. Furthermore, the total consumption of
all three outputs is also available. All meter values can be sent cyclically, on request or when a start or
stop event has occurred such as a time, operating period or when a defined consumption threshold is
reached. Furthermore, when a stop event occurs, the assigned output can be switched.
For each output the active power, current and voltage as well as further electrical variables (apparent
power, crest factor, power factor and frequency) can be measured. The measured values are made avail-
able via the ABB i-bus
dershoot of a defined threshold occur, a warning can be sent or the output switched.
The ETS application also enables simple load management (load control), where up to ten Energy Actua-
tors can be interconnected.
Furthermore, the switch actuator functionality of the ABB i-bus
ry output.
The electrical loads connected to the three floating switch outputs can be switched via KNX or manually
with manual actuation directly on the device.
1.1

Using the product manual

This manual provides you with detailed technical information relating to the function, installation and pro-
gramming of the ABB i-bus
using examples.
This manual is divided into the following sections:
Chapter 1
Chapter 2
Chapter 3
Chapter 4
Chapter A
®
KNX enhances the living quality, comfort and safety and can be easily
®
KNX Energy Actuator SE/S 3.16.1 is a switch actuator, which records the energy con-
®
KNX. They can be monitored with threshold values. Should an overshoot or un-
®
KNX Energy Actuator SE/S 3.16.1. The application of the device is described
General
Device technology
Commissioning
Planning and application
Appendix
®
KNX provides the opti-
®
KNX Switch Actuators is available for eve-
SE/S 3.16.1 | 2CDC 505 084 D0203 3

Advertisement

Table of Contents
loading

Table of Contents