Diagnostic Options - Honeywell ACUIX User Manual

High speed dome camera
Hide thumbs Also See for ACUIX:
Table of Contents

Advertisement

On-Screen Setup Menus

Diagnostic Options

102
Select 4 from the Main Menu to access the
Diagnostic Options menu. Diagnostic
menus are designed for assisting service
technicians in troubleshooting.
Coordinates
Selecting 1 toggles the Pan and Tilt
Coordinates display ON or OFF (default).
When you exit programming, the
coordinates are displayed. The pan and tilt
coordinates are displayed in degrees.
Error Table
The error table lists the 64 bytes (two digit hexadecimal number) that have been entered
into the error table. Some errors are represented by single bytes (2 digits) and some are
represented by 2 bytes (4 digits). Not all entries are actual errors—some are indications
of such things as normal power down and power up operations. (The codes used in the
error table can be seen by selecting option 5 Display Error Tbl. Codes).
Select 2 to turn the Error Table display ON or OFF (default).
Clear the Memory
Select 3 to Clear the Memory.
Select Y to clear the memory, N to cancel,
and ESC to exit.
DIAGNOSTIC OPTIONS
1 Coordinates ............ OFF
2 Error Table ............ OFF
3 Clear the Memory
4 Clear the Error Table
5 Display Error Tbl. Codes
6 Restore Default Settings
7 Scan and Dome Reset
ESC to Exit
Pan = xxx.xx..Tilt = xx.xx..Z = XXX.XX
CLEAR MEMORY
****EXTREME CAUTION****
This will delete all of the
Alarms Presets, Preset Tours
and Sectors that are stored
in memory. Are you sure you
want to do this? -Y/N-
ESC to Exit