Restore Factory Defaults

RJ45 Ethernet Connection

Document 800-01023 Rev A
02/08
SW5–7 is looked at only when the ACUIX is powered up. If this switch is ON at the time of
power up, the factory defaults will be restored. For an already powered dome, you must
place switch SW5–7 in the ON position, and then cycle the power to the ACUIX for the
factory default settings to be restored.
SW5–7
OFF
Normal Operation.
ON
Restore Factory Default settings.
Note
It is not advisable to keep this DIP switch (SW5–7) in the ON position. Once
the factory default is achieved after a single power cycling, place SW5–7
back to the OFF position.
The RJ45 connector located on the ACUIX interface board is used for production use and
testing only and has no functionality during normal dome use. This will not damage your
ACUIX dome, but may affect your network. Honeywell recommends you DO NOT connect
your network to the RJ45 connector.
ACUIX High Speed Dome User Manual
27