Switch Settings
Address Examples
DIP Switch Address Override
Factory Defaults
26
1.
To set the camera address to 1, set SW1 = 1, SW2 = 0, SW3 = 0, SW4 = 0
(CAM - 0001).
2.
To set the camera address to 125, set SW1 = 5, SW2 = 2, SW3 = 1, SW4 = 0
(CAM - 0125).
Note
If the ACUIX is set to address 0000, it will respond to control commands for
any address. That is, if the ACUIX is set to address 0000 and the operator
sends control commands for address 2, the ACUIX addressed 0000 will
perform the commands for address 2. No validation is performed on the
addresses by the ACUIX.
DIP Switch SW5–8 can be set so the ACUIX sets the camera address based on the rotary
switch settings or from memory. SW5–8 should be kept ON during normal operation so that
the logical address can be changed from the on-screen setup menus.
SW5–8
OFF
Logical address stored in memory overrides the DIP Switch settings.
ON
The ACUIX is forced to read from the rotary switches and overrides the logical
address stored in memory.
The factory default settings are as follows:
Protocol
Baud rate
Parity
Address
Termination
Honeywell Diamond
9600
No parity
Even
None