Message and Recovery Procedures
Error Message PM-4-LIMITS: The number of vlan-port instances on [chars] exceeded the
recommended limit of [dec].
Explanation
exceeded the recommended limit. VLANs can be counted more than once; if VLAN 1 is carried on
ten interfaces, it will count as ten VLAN ports. On some platforms bundling is also ignored for
purposes of this count; if eight interfaces on the same module are in one bundle, and the port channel
is carrying VLAN 1, it will count as eight VLAN ports. [chars] is the module name (for example,
switch or the module number), and [dec] is the recommended limit.
Recommended Action
as recommended in [dec]. Enter the show interfaces trunk privileged EXEC command to see the
total number of trunks and VLANs.
Error Message PM-4-NO_SUBBLOCK: No PM subblock found for [chars].
Explanation
name.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
Reports" section on page
Error Message PM-4-PORT_BOUNCED: Port [chars] was bounced by [chars].
Explanation
restarted the port. A port can be restarted only when the port data structures are not consistent in the
active and standby supervisors. Active ports in the link-down state are returned to the link-up state
when the port is restarted (the re-activation event). The first [chars] is the port number, and the
second [chars] is the re-activation event.
Recommended Action
Error Message PM-4-PVLAN_TYPE_CFG_ERR: Failed to set VLAN [dec] to a [chars] VLAN.
Explanation
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, open a case
with the TAC, or contact your IBM technical support representative, and provide the representative
with the gathered information. For more information about these online tools and about contacting
Cisco, see the
OL-12191-01
The total number of individual VLAN ports, counted over the module or switch, has
Reduce the number of trunks and VLANs configured in the module or switch
The port manager failed to find the subblock for this interface. [chars] is the interface
Copy the message exactly as it appears on the console or in the system log.
1-6.
During a switchover when the port was in the link-down state, the port manager
No action is required.
The platform failed to set a private VLAN type. [dec] is the VLAN ID.
Copy the message exactly as it appears on the console or in the system log.
"Error Message Traceback Reports" section on page
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
PM Messages
"Error Message Traceback
1-6.