Cisco 3110 Message Manual page 46

Catalyst switch module for ibm bladecenter system
Hide thumbs Also See for 3110:
Table of Contents

Advertisement

EC Messages
Error Message EC-5-STAYDOWN: [chars] will remain down as its port-channel [chars] is
admin-down.
Explanation
aggregation port is administratively down, all ports in the aggregation port are forced to be
administratively down. The first [chars] is the physical interface, and the second [chars] is the
EtherChannel.
Recommended Action
port to activate (unshut) the aggregation port.
Error Message EC-5-STAYDOWN: no-shut not allowed on [chars]. Module [dec] not online.
Explanation
shutdown interface configuration command because it is a member of an EtherChannel group and
that EtherChannel group has been administratively shut down. The interface has an EtherChannel
configuration, but no information is available yet about its port channel. [chars] is the interface, and
[dec] is the module.
Recommended Action
port-channel setting of the EtherChannel.
Error Message EC-5-UNBUNDLE: Interface [chars] left the port-channel [chars].
Explanation
interface, which can be a switch port or a routed port, and the second [chars] is the EtherChannel.
Recommended Action
Error Message EC-5-UNSUITABLE: [chars] will not join any port-channel, [chars].
Explanation
as a VLAN Membership Policy Server (VMPS), for IEEE 802.1x, as a voice VLAN, or as a
Switched Port Analyzer (SPAN) destination port. All of these are unsuitable configurations for
EtherChannels. The first [chars] is the interface name, and the second [chars] describes the details
of the unsuitable configuration.
Recommended Action
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
2-30
The administrative state of the aggregation port overrides that of the affected port. If the
Enter the no shutdown interface configuration command on the aggregation
An interface with an EtherChannel configuration cannot be enabled by using the no
No action is required. Wait until the module is online to find out the
The listed interface left the specified EtherChannel. The first [chars] is the physical
No action is required.
One of the interfaces cannot join the EtherChannel because it is configured for PortFast,
Reconfigure the port; remove the unsuitable configuration.
Chapter 2
Message and Recovery Procedures
OL-12191-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

3112