Chapter 2
Message and Recovery Procedures
Error Message CFGMGR-6-UNABLE_TO_NVGEN_BUSY_RUNNING_CFG: config file busy,
retrying...
Note
Error Message CFGMGR-6-UNABLE_TO_NVGEN_RUNNING_CFG: config file too large...
Note
CLS_ACC Messages
This section contains the Express Setup messages that appear when you use the Ethernet management
port to connect to the PC. In these messages, Express Setup is referred to as consoleless access.
Error Message CLS_ACC-2-CONFIG_NV_DATA: Express setup parameter committed. Default
port role will be applied
Error Message CLS_ACC-2-MODE_ENTERED: Entering consoleless access mode [chars]
Error Message CLS_ACC-2-MODE_EXITED: Complete consoleless access from mode [chars]
OL-12191-01
This message applies only to the Catalyst Switch Module 3110.
The stack master is temporarily unable to generate the stack running configuration
Explanation
because another process is generating the configuration file.
No action is required. The action will be tried again.
Recommended Action
This message applies only to the Catalyst Switch Module 3110.
The stack master is unable to generate the stack running configuration because the
Explanation
configuration file is too large.
Remove some configuration commands.
Recommended Action
After the Express Setup settings are configured, the switch becomes a configured
Explanation
switch. The default port roles are automatically applied to all ports. You can now manually modify
the port role configurations.
No action is required.
Recommended Action
Explanation
The switch enters consoleless access mode. [chars] is the name of the mode.
No action is required.
Recommended Action
The switch exits from consoleless access mode. [chars] is the mode.
Explanation
No action is required.
Recommended Action
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
CLS_ACC Messages
2-11