Cfgmgr Messages - Cisco 3110 Message Manual

Catalyst switch module for ibm bladecenter system
Hide thumbs Also See for 3110:
Table of Contents

Advertisement

Chapter 2
Message and Recovery Procedures

CFGMGR Messages

This section contains the configuration manager messages on stacking-capable switches.
Error Message CFGMGR-1-UNABLE_TO_SEND_RUN_CFG: unable to send running-cfg, bits:
[hex], retrying...
Note
Error Message CFGMGR-1-UNABLE_TO_SEND_STARTUP_CFG: unable to send startup-cfg, bits:
[hex], retrying...
Note
Error Message CFGMGR-3-ERROR_APPLYING_STARTUP_CFG: Error Applying Startup Config to
Running Config.
Note
OL-12191-01
This message applies only to the Catalyst Switch Module 3110.
The system is unsuccessfully attempting to distribute the running configuration to the
Explanation
stack member switches. [hex] is the bit representation of the switch number.
Recommended Action
Find out more about the error by using the show tech-support privileged
EXEC command and by copying the error message exactly as it appears on the console or system
log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported
problems. For more information about these online tools and about contacting IBM, see the
Message Traceback Reports" section on page
This message applies only to the Catalyst Switch Module 3110.
The system is unsuccessfully attempting to distribute the startup configuration file to the
Explanation
stack member switches. [hex] is the bit representation of the switch number.
Recommended Action
Find out more about the error by using the show tech-support privileged EXEC
command and by copying the error message exactly as it appears on the console or system log and
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting IBM, see the
Reports" section on page
This message applies only to the Catalyst Switch Module 3110.
The system encountered an error when it was automatically applying the startup
Explanation
configuration to the running configuration.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
1-6.
1-6.
"Error Message Traceback Reports" section on page
CFGMGR Messages
"Error
"Error Message Traceback
1-6.
2-9