Cisco 3110 Message Manual page 28

Catalyst switch module for ibm bladecenter system
Hide thumbs Also See for 3110:
Table of Contents

Advertisement

CLS_ACC Messages
Error Message CLS_ACC-2-NO_PROCESS: Process creation failure
Explanation
Recommended Action
Research and attempt to resolve the error using the Output Interpreter. Use the Bug Toolkit to look
for similar reported problems. If you still require assistance, open a case with the TAC, or contact
your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message CLS_ACC-2-SETUP_BTN_PRS: [chars]
Explanation
into Express Setup mode. Pressing the Mode button for more than 5 seconds does not affect an
already configured switch; the switch does not go into Express Setup mode. [chars] is the mode.
Recommended Action
Error Message CLS_ACC-3-CONFIG_ERROR: [chars]
Explanation
that mode. [chars] is the mode.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
Reports" section on page
Error Message CLS_ACC-3-NO_ACC_INTF: Failed to find a free interface as consoleless
access interface or failed to retrieve the access interface information
Explanation
access.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
Reports" section on page
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
2-12
Failed to create process to execute consoleless access.
Copy the message exactly as it appears on the console or in the system log.
Pressing the Mode button for more than 5 seconds causes an unconfigured switch to go
No action is required.
The switch is not correctly configured for consoleless access mode and cannot go into
Copy the message exactly as it appears on the console or in the system log.
1-6.
The switch cannot find an interface to be the management interface for consoleless
Copy the message exactly as it appears on the console or in the system log.
1-6.
Chapter 2
Message and Recovery Procedures
1-6.
"Error Message Traceback
"Error Message Traceback
"Error
OL-12191-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

3112

Table of Contents