Error Message PLATFORM_ENV-1-FAN: Faulty fan detected.
Error Message PLATFORM_ENV-1-FAN_NOT_PRESENT: Fan is not present.
Error Message PLATFORM_ENV-1-FRU_PS_ACCESS: [chars].
Error Message PLATFORM_ENV-1-TEMP: Abnormal temperature detected.
PLATFORM_FBM Messages
This section contains the platform fallback bridging manager (FBM) messages.
Error Message PLATFORM_FBM-4-RECOVERED: Fallback bridging recovered from resource
crunch.
OL-12191-01
Explanation
A faulty fan is detected.
If the message appears again, immediately replace the switch fan.
Recommended Action
The fan is not in the switch.
Explanation
If the fan is removable, remove and replace it into the switch. If the problem
Recommended Action
persists after insertion, replace the fan.
Explanation
The switch failed to access the power supply due to a communication problem. [chars]
is the error message.
This problem could be transient. If the problem persists, replace the power
Recommended Action
supply.
An abnormal temperature is detected.
Explanation
Recommended Action
Ensure that ambient temperature is not too high. If the problem persists, check
the switch temperature by entering the show env all privileged EXEC command.
Explanation
Fallback bridging has recovered from an earlier lack of resource.
No action is required.
Recommended Action
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide