Configuring The Sce Platform/Sm Connection; Options; How To Configure The Behavior Of The Sce Platform In Case Of Failure Of The Sm; How To Configure The Sm-Sce Platform Connection Timeout - Cisco SCE8000 Configuration Manual

Service control engine
Table of Contents

Advertisement

Chapter 9
Managing Subscribers

Configuring the SCE Platform/SM Connection

The user can configure the behavior of the SCE platform in case of failure of the Subscriber Manager
(SM):

Options

The following options are available:

How to Configure the Behavior of the SCE Platform in Case of Failure of the SM

From the SCE(config if)# prompt, type subscriber sm-connection-failure action
Step 1
force-failure|none|remove-mappings|shut and press Enter.

How to Configure the SM-SCE Platform Connection Timeout

From the SCE(config if)# prompt, type subscriber sm-connection-failure timeout interval and press
Step 1
Enter.
OL-16479-01
Options, page 9-23
How to Configure the Behavior of the SCE Platform in Case of Failure of the SM, page 9-23
How to Configure the SM-SCE Platform Connection Timeout, page 9-23
If SM functionality is critical to the operation of the system — configure the desired behavior of the
SCE platform if any loss of connection with the SM (may be due either to failure of the SM or failure
of the connection itself).
If SM functionality is not critical to the operation of the system — no action needs to be configured.
action — the action to take in case of failure of the SCE platform/SM connection
force-failure — force failure of SCE platform. The SCE platform then acts according to the
behavior configured for the failure state.
remove-mappings — remove all current subscriber mappings.
shut — the SCE platform shuts down and quits providing service.
none (default) — take no action.
interval — the time interval, in minutes, after which the connection is timed out
Configuring the SCE Platform/SM Connection