How To Verify Operational Status; How To View The User Log Counters; Managing Configurations - Cisco SCE8000 Configuration Manual

Service control engine
Table of Contents

Advertisement

Chapter 3
Basic Cisco SCE8000 Platform Operations

How to Verify Operational Status

After all the ports are connected, verify that the Cisco SCE8000 is not in a Warning state.
Step 1
On the front panel of the Service Control module, examine the Status LED; it should be green.
To display the operation status of the system, at the Cisco SCE8000# prompt, type show system
Step 2
operation-status and press Enter.
A message displaying the operation status of the system appears. If the system is operating in order, the
following message appears:
System Operation status is Operational.
If the Status LED is red or flashing amber, the following message appears:
System Operation status is Warning
Description:
1. Power Supply problem
2. Line feed problem
3. Amount of External bypass devices detected is lower than expected amount

How to View the User Log Counters

View the user log for errors that occurred during the installation process.
At the SCE# prompt, type show logger device user-file-log counters and press Enter.
Step 1
Examples for Viewing the User Log Counters
The following example shows the current User-File-Log device counters.
SCE#show logger device user-file-log counters
Logger device User-File-Log counters:
Total info messages: 1
Total warning messages: 0
Total error messages: 0
Total fatal messages: 0
If there are "Total error messages" or "Total fatal messages", use the show logger device user-file-log
command to display details about the errors.

Managing Configurations

OL-16479-01
Viewing Configurations, page 3-4
How to Save or Change the Configuration Settings, page 3-5
Restoring a Previous Configuration, page 3-7
Managing Configurations
Cisco SCE8000 Software Configuration Guide
3-3

Advertisement

Table of Contents
loading