Chapter 5 Web GUI Setup and Monitoring

Setting up the Channel Selections

Note: If the unit is in a disaster recovery or NIT retune mode, an error message is
displayed, informing you that any changes made to the page will interrupt the
disaster recovery or NIT retune process. The error message appears when you load,
refresh, or apply changes to the page. For more information on NIT retune, see NIT
Retune Recovery (on page 11). For more information on disaster recovery, see
Disaster Recovery (on page 8).
1
From the user interface of the D9854/D9854-I, choose Input > Channel
Selection. The Channel Selection page is displayed.
2
Enter a channel number for up to 16 program entries. Alternatively, choose an
available from a drop-down list.
Note: Only PE1 supports PowerVu descrambling. Do not assign PowerVu
channels to PE2 to PE16. If any PowerVu channels are assigned to PE2 to PE16,
all service PIDs associated with these channels will be dropped from the
transport output.
3
Click Apply.