Warning
Message
Type
D/R Rolloff
Set
Invalid
D/R Rolloff
Clear
Invalid
D/R LO Freq
Set
Mismatch
D/R LO Freq
Clear
Mismatch
Message
Cause/Remedy
Rolloff factor
Cause: The selected
invalid for DVB
Rolloff factor value for
for Backup (list
the identified Backup
of affected DR
Transport is not valid
Backup
for the selected DVB
Transports)
system.
Remedy: Contact your
PNC uplink
administrator to check
the tuning parameters
and RF Input settings for
the identified disaster
recovery backup
transports.
cleared
LO frequency
Cause: The selected LO
mismatches
Frequency from RF
tuning for
Input settings is in
Backup (list of
conflict with the
affected DR
calculated L-Band
Backup
frequency of the Backup
Transport(s) that use
Transports)
that RF Input.
Remedy: Contact your
PNC uplink
administrator to check
the tuning parameters
and RF Input LO
frequencies for the
identified disaster
recovery backup
transports.
cleared
Description
The Disaster Recovery
Table received from
the uplink is invalid.
The error is cleared
before re-validating
tuning.
The Disaster Recovery
Table received from
the uplink is invalid.
The error is cleared
before re-validating
tuning.
ID
99370
99370
99380
99380
367