Chapter 6 Service and Maintenance
Warning
Message
Type
CAT timeout #
Set
CAT timeout #
Set
CAT timeout #
Clear
DRT timeout #
Set
DRT timeout #
Set
DRT timeout #
Clear
354
Message
Cause/Remedy
CAT timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
CAT is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
CAT fault cleared –
DRT # timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
DRT # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
DRT fault cleared –
Description
Conditional Access
Table was never
received.
No longer receiving
Conditional Access
Table.
–
Disaster Recovery
Table was never
received.
No longer receiving
Disaster Recovery
Table.
–
ID
76000
76000
76000
77000
77000
77000