Setting up SDI

1
From the user interface of the D9854-I or D9854 with SDI, choose Audio & Video
> SDI. The SDI page is displayed.
2
Set the M1 Port Type and M2 Port Type (SDI or ASI).
3
In the SDI VANC Service Setup & Status area, check the Enable check box next
to the listed services/outputs (AFD, EIA-708, DPI, SMPTE-2031, SDP-OP47,
and/or Multi-OP47 to enable the selected outputs in SDI.
a
In the Line Offset field, enter the offset number from the Switch line field
displayed in the status table below.
b The Active column displays whether the service is present and inserted.
c
The Adj column displays the line number where the service is expected to be
inserted by hardware. If Multiline is supported, the Adj line number is set to
Switch + Line Offset. If Multiline is not supported, the Adj value is set to
Switch + 2.
d The L-F1 and L-F2 columns display on which line on Field 1 and Field 2 the
service is inserted. If the service is not inserted, 0 is displayed.
e
The Lines column displays the number of lines per frame used to send data
for the service.