Floor Mount Hardware

Two or four customer-supplied 12-volt reserve batteries can be connected to the system to
maintain normal operation during a power failure (see
charged state by the standard power supply and must be connected when the system is operating
normally. Fully charged batteries must be connected, and when normal AC power is available,
batteries cannot be connected after/during an actual power failure.
Table 21
Typical Reserve Power Duration Estimates (in hours)
Number of Cabinets
2 batteries
4 batteries
Discharge Current
Underwriters' Laboratory (UL) and local electrical codes require certain standards for connecting
commercial AC and reserve power to the Strata DK424 system.
assemblies may be required to meet UL and local electrical code standards.
Floor Mount Hardware
The lightweight and compact design enables easy wall or floor mounting. The RFIF hardware kit
is needed for floor mounting (see
reserve power must be connected to the RCCB conduit connection box option by a licensed
electrician. Wall mounting the system does not require special hardware.
Table 22
Cabinet Power, Reserve Power, and Floor Mount Hardware Assemblies
Assembly
RBTC1A-2M
PBTC-3M
RBDB2
RC7C1A-1.7M
RFIF
28
1
16.0
32.0
3.5A
Table
Reserve Power Cable – Two cables are required for up to six cabinet systems and three are
required for seven cabinet reserve power installations (for current carrying capacity) when
connecting reserve (battery) power to three or more cabinets (wall mount). RBDB2 is also
required for connecting battery terminals—see "RBDB2" below. A licensed electrician must install
this item to retain UL listing and/or local electrical code compliance.
Reserve Power Cable – Connects cabinet Power Supply to battery terminals. If reserve power is
connected to one or two cabinets (wall or table mount), one cable is required for each cabinet. A
licensed electrician must install this item to retain UL listing and/or local electrical code
compliance.
Battery Distribution Box – Distributes reserve power when three or more cabinets require
reserve power (floor or wall mount). Six RBTC2A-1.5M cables are provided with the RBDB2
distribution box to connect up to six DK424 power supplies to the battery distribution box. An
RC7C1A-1.7M is also required for a seventh cabinet.
Cabinet 7 Cable Kit – Provides long data cable to connect the sixth Expansion Cabinet to the
DK424 Base Cabinet. Provides a long battery cable to connect RBDB2 battery distribution box to
the sixth Expansion Cabinet power supply. Data and battery cables used for seven cabinet
installations only.
Floor Mount Fixture Kit – Provides two metal stands for mounting three or more cabinets on
floor; supports up to seven cabinets. Three pairs of wall brackets (RWBF) are supplied with RFIF.
Wall brackets are needed to secure floor-mounted systems to the wall for safety purposes (not
required for wall-mounted cabinets).
Table
21). The batteries are kept in a highly-
2
3
4
8.0
5.0
3.7
16.0
10.0
7.5
6.7A
9.9A
13.1A
22). If floor mounting three or more cabinets, AC and
Function
5
6
3.09
2.5
6.0
5.0
16.3A
19.5A
Table 22
describes which
Strata DK General Description
7
2.1
4.2
22.7A
5/99