5
Adjustment > Basic Adjustment > Side Registration/Skew Adjustment > Checking adjustment value

Side Registration/Skew Adjustment

In the case of shaky vibration on this equipment (due to large operating level of the side
registration unit) or large skew, follow the steps below to execute adjustment for side
registration/skew.
■ Checking adjustment value
● Preparations
1) Turn ON the power of the finisher.
2) Turn ON the power of the host machine to be on to be on standby.
3) Open the front cover and put the door switch tool into the door switch [1].
5
Adjustment > Basic Adjustment > Side Registration/Skew Adjustment > Checking adjustment value
4) Remove the switch cover [1] of the inner cover (lower).
• 1 screw [2]
● Procedure
1) Set DIP switch SW382 [1] on the switch PCB as shown in the figure (1, 4, 6, 8: ON), and
press ENTER (SW385) button [2], resulting in "0" blinks on the LED [3].
F-5-11
2) Place a sheet of A4 or LTR paper and set in ADF or the copyboard mode.
And set "3" for copy count to execute printing.
SW382
SW381
SW383
SW384 SW385
(-)
(+)
ENTER
F-5-13
5-6
F-5-12