Xilinx Virtex-7 FPGA VC7222 Getting Started Manual page 13

Characterization kit ibert
Hide thumbs Also See for Virtex-7 FPGA VC7222:
Table of Contents

Advertisement

Attach the Samtec BullsEye connector to the GTH Quad 115
indexing pins on the bottom of the connector with the guide holes on the board. Hold the
connector flush with the board and fasten it by tightening the two captive screws.
X-Ref Target - Figure 1-5
Figure 1-5: BullsEye Connector Attached to GTH Quad 115
GTH Transceiver Clock Connections
See
Figure 1-2
inputs. Connect these cables to the SuperClock-2 module as follows:
CLK0_P coax cable → SMA connector J5 (CLKOUT1_P) on the SuperClock-2 module
CLK0_N coax cable → SMA connector J6 (CLKOUT1_N) on the SuperClock-2 module
Any one of the five differential outputs from the SuperClock-2 module can be used to source
Note:
the GTH reference clock. CLKOUT1_P and CLKOUT1_N are used here as an example.
VC7222 IBERT Getting Started Guide
UG971 (Vivado Design Suite v2015.1) April 27, 2015
to identify the P and N coax cables connected to the CLK0 reference clock
www.xilinx.com
Chapter 1: VC7222 IBERT Getting Started Guide
(Figure
1-5), aligning the two
13
Send Feedback

Advertisement