Measurements With Touch Trigger Probe (Meas, Meaw) - Siemens Sinumerik 840D sl Programming Manual

Job planning
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

4.7

Measurements with touch trigger probe (MEAS, MEAW)

Function
The "Measure with touch-trigger probe" is used to approach actual positions on the
workpiece. On the probe's switching edge, the positions for all axes programmed in the
measurement block are measured and written to the appropriate memory cell for each axis.
Programming measurement blocks
The following two commands are available for programming measurement blocks:
• MEAS
The MEAS command is used to delete the distance-to-go between the actual and setpoint
positions.
• MEAW
The MEAW command is used in the case of measuring tasks where the programmed
position always needs to be approached.
MEAS and MEAW are non-modal; they are programmed together with motion operations. The
feedrates and interpolation types (G0, G1, etc.), as well as the number of axes, must be
selected as appropriate for the measuring task at hand.
Job planning
Programming Manual, 02/2011, 6FC5398-2BP40-1BA0
4.7 Measurements with touch trigger probe (MEAS, MEAW)
Special Motion Commands
271